AMS AS5 Series Kullanım Kılavuzu
AS5xxx-EK-USB-PB – UART Programmer Operation Manual
1.1

Communication

The Mini-USB socket is used for communicating with the computer. Therefore, a Mini-USB to USB
cable is necessary. The board is using a FT232R – USB-to-UART IC by FTDI. Therefore the
installation of the VCP (Virtual COM Port) is necessary to detect the USB device as a COM Port.
The driver can be downloaded from the official FTDI website using following link:
http://www.ftdichip.com/Drivers/VCP.htm
1.2

Power supply

By default the 5V supply voltage is provided by the USB interface. Depending if the jumpers J3, J4
and J5 are open or closed the supply source can be switched to external power supply.
Figure 3: Jumper configuration
J3
SET
NC
ams Application Note, Confidential
[v1-20] 2014-Dec-03
J4
SET
NC
J5
Supply source
NC
External
SET