3. Remove hose clamp to separate pump from adapter
(below left).
4. Disconnect support strap (below center).
5. To remove pump, slide pump off sump at seal ring (below
right). The seal ring can't be field removed from the heat
pump.
6. Disconnect the two (2) pump wire harnesses (below left).
To remove the small connector for the sensor harness with
black wires, unlatch it from it's terminal (below center).
7. If necessary, remove the adapter by removing four (4)
screws (below right).
TIP: The replacement heat pump comes with motor, pump, seal
ring and hose clamp.
NOTE: The motor can't be separated from the pump and the
seal ring can't be field installed.
702_58300000130262_ara_en_c
5.13
Float (safety system)
Tools needed:
T20 Torx, #2 Phillips & small flat blade
screwdrivers.
The float is best accessed from the bottom of the dishwasher by
flipping it upside-down or on it's back. Several plastic pieces
snap into place and must be carefully removed in sequence.
1. Remove toe kick – section 5.1.4.1.
2. Flip dishwasher for access – section 5.1.6.1.
3. Unscrew one housing screw (below left) and push one
cover tab (below right) to remove cover from float
assembly.
4. Float lever has tabs which lock onto the knob of the push
rod. Carefully push the push rod knob away from the lever
(below left).
5. Remove the float housing screw and remove the float
housing with lever (below center).
6. Remove the wire harness (below right).
Page 34 of 50