Burner dimension for each size is listed in table 2. Using SiC recuperator.
Burner
A
Model
SRB025
Rp1
SRB036
Rp1
SRB060
Rp 1½
SRB100
Rp 2
SRB180
Rp 2
4.2 Installation of the burner
1.
Preparation before burner installation
Before install burner into radiant tube, make sure all burner parts are in good condition, no
cracks on SiC recuperator and inner tube.
Check burner mounting bracket is solid and strong to support burner and radiant tube
Before the pipe is connected to the burner, it must be purged in advance to prevent welding
slag or other debris from entering the burner and affecting the normal operation of the
burner. If you need to perform pipeline welding after installation, make sure that no welding
slag or molten material falls into the pipeline or burner during the welding process.
2.
Burner installation
Burner orientation can be adjustable.
Once the exhaust gas outlet direction is decided, then the combustion air inlet can be installed
at any horizontal or vertical position, refer to Fig 4.
The gas inlet can also be adjusted by 45 degrees, refer to Fig 5.
Anderson Thermal Soluions(Suzhou)Co., Ltd
Table 2 Burner dimension
G
E(mm)
F(mm)
Rp ½
Rp 1 ¼
Rp ½
60
Rp ½
60
Rp ½
76
Rp ¾
114
Figure 3: Burner dimension
F'(mm) L
(mm) L
a
178
210
240
290
240
290
276
330
368
445
4
(mm) T(mm)
g
60
121
10
60
213
14
60
213
14
83
264
14
95
299
14