Installation Guide
This procedure is designed as an installation aid. Skilled tradespeople that are familiar with general construction and electrical
installation techniques should pe orm the installation. Licensed electricians should provide electrical installation connections.
Installations and connections should be done in accordance with all national and local codes and permits. In no way is this
document intended to construe warranty or fitness of use of the products described, nor is it intended to provide safety instruction
for those installing the product.
WARNING
Before proceeding with installation or service maintenance of this product.
• Disconnect power to reduce electrical shock risk.
• Review the entire Installation Guide.
• Inspect this properly packaged product for any damage that may have occurred during transit.
• Verify product application complies with manufacturer design recommendations.
• Verify the availability of necessary tools and incidental material.
• Verify applicable code requirements. Field assembly and installation are subject to acceptance by local inspection authority.
• Appropriate safety equipment to be determined by end user, per applicable safety standards and precautions.
Type-A Bracket Installation (Without visor)
1-1
160.0mm
155.0mm
90°
1-3
Angle adjustment scale:
ISF Series Installation Guide
*Due to the constant improvements in product development, individual parameters might change. Please refer to our sales or R&D team for most up-to-date content as
specifications are subject to change without notice.
1-2
Torque of 81Nm
Horizontal rotation
Tools:
angle: ±63°
Vertical rotation
angle: 90°
8mm inner
hexagon wrench
M10 socket
hexagon screw
10mm inner
Torque of 142Nm
hexagon wrench
M12 socket
hexagon screw
126°
Safety rope
Ø11.5mm
Ø62.0mm
Ø85.0mm
1-4
Torque of 4.8Nm
Tools:
Phillips
screwdriver
M4 cross countersunk
head screw
Phillips
screwdriver
Torque of
2.2Nm
M4 cross countersunk
head screw
20mm wrench
Torque of
M16 waterproof
240Nm
connector
The first step:
1) Fix the lower bracket on the lamp cap radiator with 4 M8
inner hexagon screws with a special tool and a torque of
41NMn, as shown in Fig (1) and Fig (2)
Fig. (1)
M8 screws
Cap radiator
Lower bracket
Fig. (2)
The third step:
First put the lamp holder hanging groove into the mount-
ing screw of the upper bracket, and then fix the lamp
holder and the upper bracket with the M12 inner hexagon
screw, and adjust the installation Angle of the lamp holder
and the bracket according to the design, and then use
special tools: with 142Nm torque to fix the M12 screw tightly.
Fig (5).
Fig. (5)
Hanging screws
Hanging slot
Screws
Lamp holder
The second step:
1) Adjust the Angle of bracket and lamp pole according to
the Angle simulated by computer.
2) Use special tools: fix the upper bracket on the lamp pole
with two M10 screws with a torque of 81Nim, as shown in
Fig (3) and Fig (4).
Fig. (3)
Fig. (4)
The fourth step:
Then the lamp holder and the junction box waterproof line
of the male and female head connection is fixed. As shown
in Fig (6) and Fig (7).
Fig. (6)
Fig. (7)