Autonics ADS-SE1/2 Manuel - Sayfa 6
Aksesuarlar Autonics ADS-SE1/2 için çevrimiçi göz atın veya pdf Manuel indirin. Autonics ADS-SE1/2 6 sayfaları. Door side sensor
Caution For Using
1. When two channels of sensor are mounted closely, it
may cause mutual interference by the emitter of other
sensor. Therefore, please install them to avoid the
interference by exchanging the head of Emitter and
Receiver and by keeping the distance between the
heads in more than 50cm.
2. When sensor head is installed on the ceiling or floor
closely, it may cause malfunction by receiving the
reflected beam. Therefore, please install it by keeping
the suitable height (more than approx. 50cm) from the
ceiling or floor.
3. When the target is a translucent or small object (Max.
Ø15mm) it may not detect as the light transmits them.
4. When wire sensor in the same pipe laying with the high-
tension wire or power line, it may cause malfunction.
Therefore, please use separated wiring or pipe laying.
5. What sensor is used in much dusty or corroded place, it
may cause malfunction. Please avoid these places when
installing.
Economical Door Side Sensor
6. When making the length of the wiring (power wire or
output wire) long, it may cause malfunction by surge etc.
7. When the lens of sensor head is polluted by dust etc.,
please clean it by dried cloth slightly.
Do not use organic solvent like thinner.
8. When switching mode power supply is used as the
source of supplying power, please ground F.G. terminal
and install a condenser for removing noise between 0V
and F.G. terminal as following drawing.
Switching
Power
mode
12-24VDC
power supply
(S.M.P.S.)
F.G.
Door side
Power
sensor
C (0.001 to 0.1㎌/400V):
(Controller part)
Condensor for removing
noise
Frame
(A)
Photoelectric
Sensors
(B)
Fiber
Optic
Sensors
(C)
Door/Area
Sensors
(D)
Proximity
Sensors
(E)
Pressure
Sensors
(F)
Rotary
Encoders
(G)
Connectors/
Sockets
(H)
Temperature
Controllers
(I)
SSRs / Power
Controllers
(J)
Counters
(K)
Timers
(L)
Panel
Meters
(M)
Tacho /
Speed / Pulse
Meters
(N)
Display
Units
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
(T)
Software
C-21