Autonics ADS-SE1/2 Manuel - Sayfa 5

Aksesuarlar Autonics ADS-SE1/2 için çevrimiçi göz atın veya pdf Manuel indirin. Autonics ADS-SE1/2 6 sayfaları. Door side sensor

Autonics ADS-SE1/2 Manuel
ADS-SE1/2
Indicator
Indicator
Connected
sensor
OUT1 (red)
1-channel
(ADS-SE1/2)
2-channel
(ADS-SE2)
※ For ADS-SE2, OUT1 indicator (red) is for Receiver status set sensitivity by Emitter of 1-channel and OUT2 indicator (green) is for Receiver
status set sensitivity by Emitter of 2-channel.
※ If lack of sensitivity occurs by not-matched optical axes or pollution on the lens of emitter/receiver during self diagnostic function,
for ADS-SE1, the OUT1 indicator (red) turns ON. For ADS-SE2, the OUT indicator of the channel lack of received light turns ON.

Operation Check

Please check the operation flow chart below.
Operation
Power
OFF
Status
Indicator
(OUT1 red/OUT2 green)
Relay
N.O.
OPEN
output
N.C.
CLOSE
status

Troubleshooting

Malfunction
It does not work.
Sometimes
it does not work.
It is operated even if
people does not enter in
sensing area.
C-20
Status
OUT2 (green)
After setting sensitivity
Sensitivity setting success
Sensitivity setting failure
-
-
1, 2-channel sensitivity
setting success
1-channel sensitivity setting success,
2-channel sensitivity setting failure
-
1-channel sensitivity setting failure,
2-channel sensitivity setting success
-
1, 2-channel sensitivity
setting failure
-
• Normal operation
• No human or any material
between sensors
OPEN
CLOSE
Cause
Power voltage
Cable disconnection, incorrect connection
Rated sensing distance
Pollution by pollutant on the lens of Emitter Receiver.
Rated sensing distance
There are obstacles between Emitter and Receiver.
There is equipment generating strong noise or ratio
wave (Motor, Generator, High-tension wire).
In operation
Received light
Emitter disconnection or
sensor cable extention
Lack of sensitivity
Interrupted light
1, 2-channel received light
2-channel lack of sensitivity
1-channel received light,
2-channel interrupted light
1-channel lack of sensitivity
1-channel interrupted light,
2-channel received light
1, 2-channel lack of sensitivity or
emitter disconnection
1, 2-channel interrupted light
Human or material is passing
between sensors
(when cutting off the transmitted
beam)
CLOSE
OPEN
Troubleshooting
Check the power cable and adjust power voltage.
Please check wiring and terminal.
Use it in rated sensing distance.
Remove the pollutant.
Use it in rated sensing distance.
Remove obstacles.
Keep away from the equipment generating strong
noise or ratio wave.
: ON,
: Flash,
: OFF
: ON, : OFF
After human or material is
passed
OPEN
CLOSE