4.
MOUNTING
Choose a vertical surface near approved ground but away from down spouts, permanent water
sprinklers, and other water sources.
To wall-mount the unit, select #8 wood screws (and washers, if needed behind screw head), or
hardware appropriate for the wall surface (Figure 2).
5.
GROUND THE UNIT
Step 1:
Open cover.
Step 2:
Pierce grommet and feed #6 AWG ground wire into the unit. Ground to the ground
stud or optional ground lug.
Open cover
using can wrench
STANDARD RECOMMENDED PROCEDURE 205-451 | ISSUE 3 | MAy 2019 | PAGE 3 OF 4
Wall-mount
#8 Wood screw,
add washer if needed.
Ground Wire
Conduit-mount
Use cable tie or
large hose clamp.
Feeder Cable
Figure 3 — Grounding and Feeder Cable Installation
TPA-3690
Figure 2 — Mount the Unit
Strain-relief Clamp x 2
Use spacers to prevent
crushing cable
Corning Flat
Corning
SST-Drop™
ROC™ Cable
Cable
2 spacers
3 spacers