Fronius TPS 4000 Kurulum Talimatları Kılavuzu - Sayfa 11

Kaynak Sistemi Fronius TPS 4000 için çevrimiçi göz atın veya pdf Kurulum Talimatları Kılavuzu indirin. Fronius TPS 4000 20 sayfaları. Second earthing socket at rear
Ayrıca Fronius TPS 4000 için: Kurulum Talimatları Kılavuzu (20 sayfalar)

Fronius TPS 4000 Kurulum Talimatları Kılavuzu
Mounting the se-
cond earthing
(3)
socket at the re-
ar
(1+9)
Mounting the second earthing socket
Threading in the cable
Connecting the cable to the front current socket
(g)
(8)
(2)
(k)
(j)
(i)
(h)
(8)
(3)
Mount the rear (-) current-socket
1
(1), complete with its blanking cap
(9):
-
Insert the rear (-) current-so-
cket (1), working from the out-
side towards the inside
-
Insert insulating washer
-
Screw on the hexagonal nut
-
Tighten the hexagonal nut with
the torque wrench, width 32
-
Thightening torque 35 Nm
IMPORTANT! The recess in the cur-
rent socket must point downwards.
Thread the cable (8) through the
2
rubber lead-throughs (f) and (g)
(f)
Connect the cable to the front cur-
3
rent socket (1):
-
Put the belleville spring was-
her (i) over the hexagon head
Housing
screw (h)
-
Put the star (j) over the hexa-
gon head screw (h)
-
Put the cable lug of the cable
(8) over the hexagon head
screw (h)
-
Put the cable lug of the exis-
ting current cable (k) over the
hexagon head screw (h)
-
Screw the hexagon head screw
(1)
(h) into the current socket
-
Tighten the hexagon head
screw (h) with the torque
wrench, width 19
-
Thighting torque 15 - 35 Nm
11