Installing 1010 VoIP Module onto 1010 motherboard
1.
Observing proper ESD procedures, remove the 1010 VoIP module from its ESD packaging and
inspect for damage. Pay special attention to the mating connectors.
2.
Position the module over the four standoffs on 1010 Motherboard.
3.
Align the connectors on the 1010 VoIP Module with the connectors on the 1010 Motherboard.
Before pushing the connectors together, ensure the connectors are properly aligned.
4.
Apply pressure with the thumbs and index fingers on the edges of a module forming a window
around the connectors. The level of pressure should not be excessive; it should be enough to
firmly seat the 1010 VoIP module. CAUTION: DO NOT APPLY PRESSURE TO ANY OF THE
COMPONENTS ON THE MODULE
5.
Install the four (4) Phillips pan head screws to secure the module. Do not over-tighten the screws.
(Recommended torque: 4 in-lbs (.34-.56 N-M)).
6.
Once module is securely fastened to the 1010 Motherboard, reinsert the 1010 Motherboard Tray
into IMG chassis. Align the rail on each side of the tray with the guides on the inside of the
docking station.
7.
Verify the ejectors are in the up position. Slide the tray in until the power connectors and signal
connectors initially mate (the ejectors will start to move down). Use ejectors to firmly seat the
1010 Motherboard tray into the IMG chassis.
Cautions:
Do not force the tray into the IMG chassis connectors. If any resistance occurs when mating with
the docking station, slide 1010 Motherboard out and reseat connectors. Using undue force could
damage the unit.
The guides only provide general alignment to the power and signal connectors. The guide pins
on the main board and I/O card are self-aligning and will provide final alignment for the
connectors.
The tray guides also act as the conduit for any Electrostatic Discharge (ESD) as the tray initially
mates with the docking station.
8.
When the tray is seated and the connectors are mated, push the ejectors down and tighten the
captive fasteners. Reconnect power and cabling.
9.
Switch the power to ON (1) at rear of docking station and allow software to load. To configure the
module, start GCEMS and ClientView. See the Dialogic Manuals website located at
http://www.dialogic.com/manuals
Dialogic Corporation
for information on starting GCEMS and ClientView
Part # 07-8740-02