k)  The  level meter must  not be installed  in  places 
with direct solar radiation and must be protected 
against weather conditions.
l)  In case the installation at places with direct solar 
radiation  is  inevitable,  it  is  necessary  to  mount 
a shielding cover above the level meter (Fig. 8).
m)  To lower the minimum distance to the medium meas-
ured, a reflection board made from solid, even and 
smooth material can be installed together with the 
level meter (Fig. 10). Subsequently, the tank can be 
filled nearly up to the maximum volume. The solution 
is suitable for open tanks and reservoirs.
n)  Scattering or attenuation of the ultrasonic signal can 
result if the surface level has been moderately stirred 
or rippled as a consequence a stirrer's operation, 
inflow of liquid and the like. Consequently, measuring 
range or unreliable level meter's functioning might
follow (Fig. 11). 
o)  False  surface  reflections  of  the  ultrasonic  signal 
might result as a consequence of rotating mixer's
blades that ripple the surface level and thus cause 
unreliable level meter's functioning (Fig. 12).
p)  The level meter should not be installed at places 
where ultrasonic signal false reflections caused 
by stirrer blades might occur (Fig. 13).
Fig. 10: Moderately stirred
surface
© Dinel, s.r.o.
ULM–53L
!
Fig. 11: Intensely stirred
surface
Fig. 8: Direct solar radiation shielding
cover
H + L = Dead zone
Fig. 9: Reflection board
!
Fig. 12: False reflection caused by
mixer blade
9