Maintenance
Warning the BundGuard system feeding the FilterSepta, automatically starts
power to the unit should be isolated before opening the lid of the FilterSepta.
Wear protective clothing when carrying out the procedure below appropriate to the type
of oil/oils present.
Solvents and degreasers should not be used when carrying out maintenance as this will
affect the separation performance.
FilterSepta 2 units should be visually checked regularly to ensure there is no significant build-up of
contaminants and actioned appropriately. The FilterSepta 2 units should be cleared of contaminants on
regular intervals. This involves removal of any silt and oil build up as well as washing down of the
coalescing filter together with cleaning of the sensor probes. We recommend that they should be
maintained every 6 or 12 months – depending on the specific site.
Technical Details
EN858
Nominal Length
Nominal Width
Nominal Depth
Nominal Size
Nominal Flow Rate
Material
Internal Parts (Excluding sensor)
Filtration Type
Total Volume
Sludge Volume
Maximum Oil Storage
Max Oil layer
Weight Empty
Class 1
1200mm
500mm
824mm
1
3ltrs/s
HDPE
HDPE
Coalescence Filter(removable)
300ltrs
100ltrs
70ltrs
150mm
54kg
Filtersepta 2 28.01.2022 Rev.0