8.3. Window „Fan"
In this window you are able to choose whether the fan shall be regulated
manually or automatically into dependence of a temperature and further
parameters. At the manual setting activate the "manual power adjustment"
and simply use the slider to adjust the power while for the option "temperature
control" the temperature of the external temperature sensor or the internal
water temperature sensor is used for an automatic regulation. You can
choose freely which sensor should be used for the regulation.
You can influence all parameters by hand which are connected with the
automatic fan regulation in the field temperature regulator. Inexperienced
users can alternatively choose one of the predefined profiles.
On the right side two scales gives information about the output voltage of the
fan header as well as the adjusted power. Moreover, the currently measured
speed of the fan is displayed under the scale.
8.4. Windows „Pump and flow rate settings"
Here you can select whether the pump shall be controlled automatically or
manually.
At the "automatic frequency settings" the frequency of the pump is
automatically set to the highest possible frequency. To this the electronics of
the pump determines permanently the position of the rotor, current
consumption, performance as well as the voltage and calculates the optimal
operating point out of this independently. To this is the frequency repeatedly
tries to get as high as possible at a stable operation. Depending on the
resistance of a system the frequency of the pumps reaches approx. 75 - 85
Hz in a normal loop.
You can adjust the pump frequency manually at the "manual frequency
settings". If the chosen value is not attainable, then the pump tries to adjust
the highest possible frequency (below your target frequency) like in the case
of the automatic frequency setting.
With the button "reset maximum pump frequency" the maximum frequency
found out currently is rejected in the automatic and in the manual mode and
the pump tries once more to find the maximum frequency.
This process also can be automated by activating that the frequency shall be
reset automatically after X minutes.
The automatic deaeration of the pump can be actievated through the option
"activate deaeration mode". In the delivery state the deaeration by jumper is
predefined as described at the beginning. To be able to start the deaeration
© 2007