Aqua Medic Kauderni CF Посібник з експлуатації - Сторінка 7

Переглянути онлайн або завантажити pdf Посібник з експлуатації для Акваріуми Aqua Medic Kauderni CF. Aqua Medic Kauderni CF 13 сторінок.
Також для Aqua Medic Kauderni CF: Посібник з експлуатації (18 сторінок)

Aqua Medic Kauderni CF Посібник з експлуатації
Fig. 2: Filter chamber Kauderni CF
1. Circulation pump DC Runner 2.2
2. Filter sponge
3. Skimmer EVO 500
4. Emergency overflow
5. Filter inlet
In the cabinet, there is a ball valve (Fig. 1, No. 8) that has to be slightly closed to control the water in the
overflow box. If the valve is closed to heavily or the return flow is blocked for some reason, the water rises in
the aquarium and flows to the filter tank through the emergency overflow. In such a case, the ball valve has to
be opened a bit further and all blockages have to be eliminated. If the overflow makes loud noises, the ball valve
has to be closed a bit more so the water is bottled up stronger so that no air is dragged along. At least in the
initial phase this has to be controlled regularly and, if necessary, to be adjusted.
With the supplied PVC tubes with moulded keys on one side for holding the nuts of the bushings (tank fittings),
these nuts can be tightened or released. The bushings have to be installed according to Fig. 3. Always re-tighten
before use. The slide ring and nut have to be mounted manually beforehand and tightened as much as possible.
The rubber slide ring must always be attached to the side of the rotable nut, the rubber gasket on the opposite
side of the panel.
7