B. OPERATION INSTRUCTIONS
WARNING: Do not use with water that is microbiologically unsafe
or of unknown quality without adequate disinfection before or after the
system.
WARNING: Do not connect power to unit until water flows from all taps
1.
Wash all filter bottle parts (except filter cartridge) with warm water
and detergent and rinse thoroughly. In addition, flush clean water
through the unit and drain out via the taps and drain plug located at the
rear of the unit. Tilt the unit back and forth to remove trapped water
from unit. Continue this process until no more water runs
out of the drain.
2.
Remove Filter Cartridge (1) from plastic, make sure not to lose the
filter cartridge O ring. Immerse filter in ambient water for 20 minutes.
Shake filter under water to remove any excess black carbon particles
and trapped air.
Note: You may see small amounts of black particles at times; these are
small pieces of carbon from the filter. These carbon particles are food grade
and are not harmful. They will not impair the performance of your filter or
unit
3.
Ensure drain plug (14) is secure on the unit and tighten in place.
4.
Ensure that the Filter Bottle O ring (7) is seated in the channel at the
top of the cooling unit. See Figure 1 for location.
WARNING: If Filter bottle O ring (7) is not in place or correctly seated
leaking may occur. When the filter bottle is removed special care must be
taken to ensure this part is not lost. Always ensure the O ring is correctly
seated prior to installing the filter bottle.
5.
Place filtered water chamber (6) onto the water cooler unit and push
down. There should be no gap between the cooling unit and the filtered
water Chamber (6)
6.
Lock the filtered water chamber (6) into position using the filter
bottle screw nut (15). Turn filter bottle screw nut (15) in a clockwise
direction. Tighten by hand only, do not over tighten. See figure 2.
7.
Place unfiltered water chamber (5) into the filtered water chamber (6)
8.
Install Filter cartridge O ring (2) onto the unfiltered water chamber filter
thread then screw the filter cartridge into place.
9.
Pour water into the unfiltered water chamber (5); allow water to filter
through to the filtered water chamber (6).
Fig 1
Fig 2
Channel for
Filter bottle
Filter bottle
O Ring
Aerial view
of cooling
unit with
filter bottle
removed
INSTALLATION AND OPERATING INSTRUCTIONS 5
screw nut