Digiflex RF159 Посібник інсталятора - Сторінка 4
Переглянути онлайн або завантажити pdf Посібник інсталятора для Контролер Digiflex RF159. Digiflex RF159 8 сторінок. 2 channel smart rf controller - 433mhz
Learning Keyfobs
A total of 250 keyfobs can be learnt, for example you can have 250 different keyfobs operating RLY1 or RLY2. You
can also spread the 250 keyfobs across both RLY1 and RLY2 using different buttons. The same keyfob can not be
programmed to operate the same relay using 2 different buttons. If a keyfob button is already learnt to RLY1 and you
learn a different button on the same Keyfob to RLY1 then the original button is overwritten by thew new button.
While learning keyfob buttons to the relays you can easily learn one keyfob to RLY1 then learn a different button to
RLY2 after each other and then learn new keyfobs after each other.
Action
Enter Keyfob
1
Learn Mode
Selecting The
2
Relay
Learn Keyfob
3
Button to Relay
Exit Programming
4
Mode
Receiver LED Indicators
The RF159 2 Way Output Module includes RED and GREEN LED indicators which provide visual feedback during sys-
tem operation. See Table 3 for information on the indicator colours and meanings.
Lable
LED Colour
RLY1
Red
RLY2
Red
RF
Green
PGM
Red
Page
4
P/N: RF159IRG Rev 1.3
Learning a Keyfob
Steps
Press RLY1 and RLY2
for 1 second
Press Relay Button To
Select (E.g. RLY1)
Press desired keyfob
button to learn
To program another keyfob or button go to step 2.
Press RLY1 and
RLY2 for 1 second or
timeout after
60 seconds
LED Legend
Fast Flash
Table 2: RF159 Keyfob Programming
LED Indicators
Purpose
RLY1 Operation /
Programing
RLY2 Operation /
Programing
Packet Receive /
Transmit / Power
Programing Mode
Table 3: RF159 Device LED's
LED's
RX: ON
PGM: ON
RLY1: Flash
RLY2: Flash
RX ON
PGM ON
RLY1: ON
RLY2: OFF
RX: Acknowledged with a singal
pulse
PGM: ON
RLY1: Flash
RLY2: Flash
RX: ON
PGM: OFF
RLY1: OFF
RLY2: OFF
Slow Flash
Steady On
Steady
OFF
Red
Red
Red
Green
In programming mode with either a 50/50 blink or solid
on as well as flashes on when the relay is operated.
In programming mode with either a 50/50 blink or solid
on as well as flashes on when the relay is operated.
Indicates power on the module and receive/transmit
data packets.
Blinks each time the system is polled by the control
panel.
-
RF
RLY1
PGM
RF
RLY1
PGM
RF
RLY1
PGM
RF
RLY1
PGM
Meaning
E&OE
Copyright © 2020
RLY2
RLY2
RLY2
RLY2