5.0 Maintenance
WARNING! Always disconnect the plug from
the socket prior to maintenance or cleaning.
To ensure a long and problem free working
life, please take the following advice:
Wash out water hose, high pressure hose,
spray lance and accessories before mount-
ing.
Clean the couplings of dust and sand.
Rinse the foam sprayer after use.
Any repair should always be made in an
authorised workshop with original spare
parts.
5.1 Cleaning of nozzle
A clogging up in the nozzle causes a pump
pressure which is too high. This is why
cleaning is required immediately.
1.Stop the machine and disconnect the
nozzle.
2.Clean the nozzle with a cleaning needle.
IMPORTANT: The needle should only be
used when the spray lance is detached!
3.Flush the spray lance backwards with wa-
ter.
5.2 Cleaning of water inlet filter
Clean the water inlet filter regularly once a
month or more frequently according to use.
Carefully loosen the filter with a screwdriver
and clean it. Check that it is intact before re-
mounting it.
5.3 Cleaning of machine vents
The machine should be kept clean so as to
let cooling air pass freely through the mac-
hine vents.
5.4 Oil level Check / Oil change
Check the oil level in the cleaner at regular
intervals. The casing has to be removed in
order to check the oil level. Change the oil in
the cleaner every 200 operating hours.
Oil grade: Alpha-Synt
Capacity: see ‚Technical Data'
Maximum filling level: up to the middle of the
oil sight glass
6.0 Storage
Frost protection
I fthe high pressure cleaner is stored in a
room in which temperatures belw freezing
may occur, anti-freeze mus be drawn in
through the puimp before storage.
During the intake of the anti-freez, press the
trigger of the spray gun 2 to 3 times. In order
to rule out any risks, the cleaner should
preferably be stored in a heated room for
some time before putting it into service
again.
Frost damages are not covered by the
guarantee!