7.0 Trouble shooting guide
To avoid unnecessary disappointments, you should check the following before contacting the
ALTO serivice organisation:
Symptom
Machine refuses to start
Motor buzzes
Machine stops
Fuse blows
Machine pulsating
Machine often starts
and stops by itself
Machine starts, but
no water comes out
In case problems other than the above occur, please contact your local ALTO distributor.
20
Cause
Machine not plugged in
Defective socket
Fuse has blown
Defective extension cable
Mains voltage is too low, or
phase failure
Pump is jammed or frozen
Incorrect cross-section or
length of extension cable
Spray gun has not been
actuated
Fuse has blown
Incorrect mains voltage
Thermal sensor activated
Fuse too small
Air in inlet hose/pump
Inadequate supply of
water
Nozzle partially blocked
Water filter blocked
Hose kinked
High pressure hoses too
long
Pump/spray handle is
leaking
Pump/hoses or accessory
frozen
No water supply
Water filter blocked
Nozzle blocked
Recommended action
Plug in machine.
Try another socket.
Replace fuse. Switch off other machines.
Try without the extension cable.
Have the electrical connection checked
Turn the motor by hand as described under
„Putting into service after prolonged storage"
Use correct cable cross-section or length,
see „Safety precautions"
Switch on cleaner and actuate the spray gun
trigger
Replace fuse. Switch off other machines.
Check that the mains voltage corresponds
to secification on the model tag.
Wait - the machine will start after a few
minutes.
WARNING! The trigger of the spray handle
must not be activated.
Change to an installation higher than the
amp. consumption of the machine.
You may try without the extension cable.
Allow machine to run with open trigger until
regular working pressure resumes.
Check that the water supply corresponds
to mains water specifications required (see
model tag)
NB! Avoid using long, thin hoses (min 1/2")
Clean the nozzle (see section 5.1)
Clean the filter (see section 5.2)
Straighten out hose.
Disconnect high pressure extension hoses
and retry
Contact your nearest ALTO Service Cen-
tre.
Wait for pump/hoses or accessory to thaw.
Connect inlet water.
Clean the filter (see section 5.2)
Clean the nozzle (see section 5.1)
GB