Etaluma LS460 Посібник із запуску - Сторінка 5

Переглянути онлайн або завантажити pdf Посібник із запуску для Мікроскоп Etaluma LS460. Etaluma LS460 14 сторінок. Lumascopes with lumaview (for use with ls560, ls460, ls600, ls620, ls720)

2. Lumaview (without an LS Microscope number in the name) now works with multiple Lumascopes,
including LS720, LS620, LS600, LS560, and LS460. The specific LS Microscope in use is selected in
Instrument Setup as described in Section II.C below.
3. Lumaview will run on Windows 7, 8, 8.1, and 10. Both desktop computers and laptops can be used, but
the best visualization correlates with monitor resolution (Note: the monitor does not affect image
resolution unless you are using a low quality monitor that affects your ability to judge focus). The
computer should have Windows .NET Framework 4.5.2 or higher installed; see
https://msdn.microsoft.com/en-us/library/bb822049%28v=vs.110%29.aspx
If your computer does not have .NET Framework 4.5.2 or higher installed, downloading Lumaview may
automatically take you to the Microsoft .NET download page. Scroll down the page to find the correct
download. This should not require a purchase. Alternately, the .NET Framework 4.5.2 can be installed
from the flash drive included with the LS Microscope. Contact Etaluma if you have any questions.
J. Downloading and Installing Lumaview
1. To download Lumaview, go to
Click on Lumaview - ZIP link to start the download and save the folder when prompted. Go to your
downloads location and click to open the Lumaview_Install_v(version#).zip file.
Alternatively, the same Lumaview Install_v(version#).zip file can be copied from the flash drive that
comes with the LS560. Verify that this file is the latest version as posted on the Etaluma website.
2. Lumaview will not run on a computer with Lumaview 500/400 or Lumaview 600-Series installed. To
uninstall either of these versions, use the procedure described in Appendix B.
Installing the new Lumaview (without an LS Microscope number in the name) will overwrite older
versions of Lumaview as well as Lumaview 720/600-Series. Therefore, in most cases, there is no need
to uninstall earlier versions.
If there is a need to revert to an older version of the software, it will be necessary to first uninstall the
current version using the procedure described in Appendix B.
3. To install Lumaview, right click on the .zip file and Open with Windows Explorer. Double click on the
.msi installer file to start the installation. If a Windows warning box about an unrecognized App
appears, click Run anyway.
You will be asked about the location; note that the default is a new Etaluma folder inside the Program
Files (x86) folder. During installation, a Device Driver Installation Wizard will open. Click to continue
(twice) and finish installing the two drivers. Installation of Lumaview will then finish. After installation,
a Lumaview shortcut (orange circle) convenient for launching the software will be present on the
desktop.
K. Connecting the LS Microscope
1. If connecting to a computer that has been off, turn computer on. Make sure computer is connected to
its monitor(s). Insert the standard USB-A end of the supplied USB cable into a USB port on your
2017.11.20
http://etaluma.com/products/downloads
LS560/460 Startup Guide
for more information.
(under the Resources tab).
5