2GIG Vario Quick Install Guide
Maximum Current Flows
3. Wire Auxiliary Devices
Use the Auxiliary Power AUX (+) COM (–) terminals to power PIRs, glass-break detectors (4-wire types), smoke detectors, audio switches,
photoelectric systems and/or any device that requires a 12VDC power supply.
4. Wire the Internal Bell
The Bell/LS terminal provides power to the internal siren. When connecting an internal sounding device, pay attention to the polarity.
It is important to position the BELL/LS DIP switch SW1 correctly. The position varies depending on the type of internal siren.
To avoid bell loop trouble, if no connections are made to an internal siren, use a 2.2KΩ resistor in its place.
5. Wire the Bell Tamper
Connect the bell tamper to the BELL TMP and COM terminals on the main panel using 2.2KΩ resistors.
IMPORTANT:
If you DO NOT use the terminal TMP BELL, remember to connect a 2.2KΩ resistor (resistor colors: red, red, red) between
the TMP and COM.
6. Wire Utility Output 1 to Activate Self-Powered Devices
Utility output 1 can be used to activate a self-powered siren or any other self-powered device.