Autonics LE4S Series Anleitung - Seite 17

Blättern Sie online oder laden Sie pdf Anleitung für Zeitschaltuhr Autonics LE4S Series herunter. Autonics LE4S Series 18 Seiten. Lcd digital timers
Auch für Autonics LE4S Series: Handbuch (17 seiten), Handbuch (6 seiten)

Autonics LE4S Series Anleitung
LE4S Series

Interval mode

It is able to make Instantaneous ON and time limit OFF
(Holding device) with using interval mode.
T : Timer
Instan-
START
taneous
Time
limit
Load
<Previous>
Change of output operation mode and
timer range
If changing output operation mode or time range,previous
reset value will be deleted.
But, UP/DOWN selection mode and lock mode are
exception.
Change of preset value
● If changing setting value while time progressing, new
preset value should be higher than previous preset
value.
Otherwise output may work while changing setting
value.
● If changing setting value while it is running, it will work as
changed setting value. Please use lock function in order
to avoid malfunction.
Noise
We test 2kV, pulse width 1㎲ against Impulse voltage
between power terminals and 1kV, pulse width 1㎲ at noise
simulator against external noise voltage. Please install MP
condensor (0.1 to 1㎌) or oil condensor between power
teminals when over impulse noise voltage occurs.
Environment
Please avoid the following places;
● Where this product may be damaged by strong impact or
vibration.
● Where there are corrosive gas or flammable gas and
water, oil, dust exist.
● Where magnetic and electrical noise occurs.
● Where there are high temperature and humidity beyond
rated specification.
● Where there are strong alkalis and acids.
● Where there are direct rays of sun.
K-36
START
Time
limit
LE4S
Load
<Interval mode>