Interval mode

It is able to make Instantaneous ON and time limit OFF
(Holding device) with using interval mode.
T : Timer
Instan-
START
taneous
Time
limit
Load
<Previous>
Change of output operation mode and
timer range
If changing output operation mode or time range,previous
reset value will be deleted.
But, UP/DOWN selection mode and lock mode are
exception.
Change of preset value
● If changing setting value while time progressing, new
preset value should be higher than previous preset
value.
Otherwise output may work while changing setting
value.
● If changing setting value while it is running, it will work as
changed setting value. Please use lock function in order
to avoid malfunction.
Noise
We test 2kV, pulse width 1㎲ against Impulse voltage
between power terminals and 1kV, pulse width 1㎲ at noise
simulator against external noise voltage. Please install MP
condensor (0.1 to 1㎌) or oil condensor between power
teminals when over impulse noise voltage occurs.
Environment
Please avoid the following places;
● Where this product may be damaged by strong impact or
vibration.
● Where there are corrosive gas or flammable gas and
water, oil, dust exist.
● Where magnetic and electrical noise occurs.
● Where there are high temperature and humidity beyond
rated specification.
● Where there are strong alkalis and acids.
● Where there are direct rays of sun.
K-36
START
Time
limit
LE4S
Load
<Interval mode>