Step 4:
If the inner plate was removed from the box to a work surface, return the plate to the box
and secure it with the latches seen in Figure 2 before installing the feeder trunk cables.
Step 5:
Before installing trunk cables, lift cable access panels as shown in Figure 15.
Step 6:
Install the trunk cables in the cradles per bullets 1 and 2 of Figure 16. Feed the cable into
the box through the cable entry locations and slide the cradle feet in the slotted openings in
the plate as shown in bullet 3 of the figure.
Figure 17
Step 7:
STANDARD RECOMMENDED PROCEDURE 003-825-AEN ISSUE 7 | NOVEMBER 2020 | PAGE 9 OF 11
If additional trunk cables are needed,
install a furcation mounting bracket to the
exterior of the box (Figure 17) and mount
the additional trunk cables to the bracket.
Route legs into the box
Figure 15
Figure 16