Default mapping of absolute encoder

7.4.2
The mappings for both PDOs are the same. The position will be transmitted in byte 0..3.
ID
DLC
181h/281h
4
Byte 0...3: Position (Object 6004h)
7.5

Timing

The minimal cycle time for TPDOs is 1 ms.
7.6

Exceptions of accurate calculation of process data

The following operations could interrupt the accurate calculation of process data such as position, speed, warnings and
alarms:
-
Changing the scaling parameters