Automatic Technology Australia Securalift GDO 2v4 Instructions d'installation et manuel du propriétaire - Page 4

Parcourez en ligne ou téléchargez le pdf Instructions d'installation et manuel du propriétaire pour {nom_de_la_catégorie} Automatic Technology Australia Securalift GDO 2v4. Automatic Technology Australia Securalift GDO 2v4 19 pages.

1. LIGHT
CODE button (White)
is
used
for
storing
or
erasing the
transmitter button
(code) you wish to
use
to tum the
courtesy
light
on the
Opener on and
off.
2.
DOOR CODE button (Blue)
is
used
for
storing
or
erasing
the
transmitter
button (code)
you wish
to
use
to
command
the
door'to
open
,
stop
or
close.
3.
CLOSE DRIYE button
(Red)
is
ur-
,
during installation
to
help
set
thEilose
tiirlt
stop
position.
Pressrng
and
holding
this button
will
move
the
door in the
close
direction
Movement stops when the button
is
released.
NOTE: The close
safety
obstruction detection is inoperable
wheneyer
the Close
I)rive button
is
used
to
move
door.
4.
CLOSE
LIMIT
Led
(Red)
.the
led is very
helpful during installation,
it
illuminates and flashes when the
door is closing
and
remains steady
on
when
the close
limit
is
activated
5.
IUTO
CLOSE button (White)
is
usbto
adjust
the auto
close time.
While holding
in
the Auto
Close
button
and
then pressing (each
press
will
increase
the time
by 5
seconds)
the
Open button
the time
is
increased,
pressing
the
Close button
will
decrease the
time.
6.
RESET button
is
used to
initialise and set
the
door/opener
operating parameters,
including
cycle
times and obstruction force
set-
tings.
Check
the installation
manual
for
other
uses.
7.
O
I
S
/
C
button (Yellow)
is
used
during installation
to
test the
open,
stop and close cycles
for the
Opener.
The
Opener has
to
be initialised by
the
Reset
button before
the O/S/C but-
ton
becomes operable.
8.
CLOSE
LIMIT
ADJUST
SCREW
(Red) is
used
to
fine
ad-
just the
close
limit
stop position.
Check
installation section
on
how
to
adjust.
9.
OPEN
LIMIT
ADJUST
SCREW
(Green)
is
used
to
fine
adjust
the open
limit
stop
position.
Check
installation section on how
to
adjust.
10.
CLOSE
LIMIT
CAM
(Red)
is
used
to
set
the
close
limit
stop
position. Check installation
section
on
how
to
adjust.
11.
OPEN Drive button
(Green)
is
used
during installation
to
help
set
the
open
limit
stop
position.
Pressing
and holding
this
bufion
wi_ll move
the
door
in
the
open
direction.
Movement
stops
when
the
button is
released.
NOTE: The open
obstruction
detection is disabled whenever the
Open
Drive button
is
used
to
move
door.
12. OPEN
LIMIT
Led
(Green)
the
led
is
very helpful
during
installation,
it
illuminates
and
flashes when
the door
is
opening
and
remains steady
on
when
the open
limit
is activated
13.
OPEN
LIMIT
CAM
(Green)
is
used
to
set
the
open
limit
stop
position. Check installation
section
on
how
to
adjust.
14.
FORCE MARGIN
SET
button is
used
to
change
the
force
pressure
when the'door
encounters
an obstruction.
Pressing
the
Force
Margin Set button and Open
or
Close button
will
increase
or
decrease
the
force. Normally
the
force pressure
is
set
automatically.
The Force Margin Set
is only
ever
used
if
other
environmental factors
(wind,
etc.) effect
the
operations
of
the Door/Opener.
15.
P.E.
Input
is
for
connection
of
Photo Electric Beams
(optional
extra)
for
extra
safety obstruction
protection.
NOTE:
P.E. SHUNT
must
not
be
removed
dherwise the Opener
will
not function correctly.
Remove
only
when
a
P.E.
is
to
be
connected
16.
EXTERNAL
RECETVER
INPUT
is
the
input where
an
extemal receiver can be
connected.
The receiver must
be
able
to
operate
of
24
vohs DC.
17. SECURALIGIIT Input
is used
for
connecting
a
Securalight
(optional extra) Monitor.
A
Securalight
is a monitor unit which
is mounted inside your home and
is
connected
to the
Opener
by
wire
cable. The monitor
indicates the
ststus
ofthe
door,
for
example
if
the
door
is
moving
or is
opened or
closed,
etc.
An
audible
beeper
sounds whenever
the door is
moved
by the Opener. The door can also
be
controlled from the monitor unit.
18. O/S
tC Inputisfor
connecting
the wired
Wall
Switch.
19.
ENGAGE
/
DISENGAGE
HANDLE
when pulled down to-
wards
door and
released
will
select
manual mode when
there is
a
power
failure. Pulling away from door
and
releasing again
will
select automatic
mode