working around such items, blocks should be used to prevent unintentional
movements. After a repair remove the blocks and check the entire machine
carefully to determine proper reassembly before POWER is restored.
 Note: The machine is supplied with bearings pre lubricated; however the
bearings should be lubricated after every 500 hours of running time.
 The machine should be inspected for dirt and debris that may have
collected during Daily Usage.
 All bolts should be checked for tightness every 6-months.

6. General Construction, Factory Settings and Adjustments

6.1. General Notes and Cautions:

 This machine is designed for a maximum of 16 gauge Steel.
 Do not exceed the maximum material thickness for the machine.
 The machine has been adjusted at factory and should not require any
changes.
 The TDFC Brake is exclusively designed as a one (1) man operation.
Failure to follow this precaution can result in serious injury.
6.2. Folder Adjustments
 The Folder pivot position is located with pillow bearing blocks.
Adjustment bolts push the bearing blocks back toward the rear of the
machine, tightening the bend. To adjust, first remove the small guards
around the pivot mechanisms, then loosen the two bolts that fasten the
pillow block bearing to the table and rotate adjustment bolt to obtain
desired brake.
 The Folder stop position is determined by the stop bolts located on the
overhead press bar. Loosen the jam nuts and adjust to set desired
brake angle.
OPERATING and PROCEDURES MANUAL
Page 6 of 12
TDFC POWER BRAKE