COMMUNICATION CONNECTIONS

Secure DMX/RDM Connection

See the DMX Wiring for a Zino LED Fixture in the diagram below:
Follow the steps below to secure the DMX/RDM Connections to the fixture.
1. Determine the present Communication Board, then secure the DMX Communication Wiring to the board based on the
local sites wiring options. The four possible options are:
• XLR - 5 Pin (P/N: 17-00005)
• RJ-45 (P/N: 17-00004)
• Insulation Displacement Connector (IDC) (P/N: 17-00003)
• Screw Terminal (P/N: 17-00002)
2. Ensure the DMX Wire Harness connection from the Controller to Communication Board has not been disrupted.
3. Set the fixtures DMX Address as needed.
NOTE:
All DMX Wiring should be compatible with Telecommunications Industry Association TIA/EIA-485 (RS-485). See the table on
Page 7 of this manual for the required DMX over CAT5e/6 Information.