- ページ 6

コントローラー HID Aero X1100のPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。HID Aero X1100 8 ページ。 Intelligent controller

HID Aero X1100 インストレーション・マニュアル
Powering
Trusted Identities

Status LEDs

LED
BATT FAIL
AC FAIL
TAMPER
IN 1
IN 2
IN 3
IN 4
ONLINE
ON for approximately 15 seconds
HOST COMM
IO INTERNAL
IO MODULE PORT 1
IO MODULE PORT 2
READER 1
READER 2
RELAY 1
RELAY 2
RELAY 3
RELAY 4
ETHERNET
*If this input is defined, every three seconds the LED is pulsed to its opposite state for 0.1 seconds, otherwise,
the LED is OFF.
6
POWER ON SELF-TEST
On then OFF
On then OFF
On then OFF
On then OFF
On then OFF
On then OFF
On then OFF
ON for approximately 1 second
ON for approximately 1 second
ON for approximately 1 second
ON for approximately 1 second
ON for approximately 1 second
ON for approximately 1 second
OFF
OFF
OFF
OFF
OFF
HID Aero™ X1100 Installation Guide
NORMAL OPERATION
OFF = Inactive, ON = Active, Flash = Fault.*
OFF = Inactive, ON = Active, Flash = Fault.*
OFF = Inactive, ON = Active, Flash = Fault.*
OFF = Inactive, ON = Active, Flash = Fault.*
OFF = Inactive, ON = Active, Flash = Fault.*
OFF = Inactive, ON = Active, Flash = Fault.*
OFF = Inactive, ON = Active, Flash = Fault.*
Off-Line / On-Line and battery status.
On-Line = A long flash ON and a short flash OFF.
Off-Line = A short flash ON and a long flash OFF.
Double flash if battery is low.
Host communication activity (Ethernet).
Internal IO module communication activity.
External IO module activity (Port 1).
External IO module activity (Port 2).
OSDP Mode = Flashes when transmitting data.
Wiegand or C&D Mode = Flashes when data is received,
either input.
OSDP Mode = Flashes when transmitting data.
Wiegand or C&D Mode = Flashes when data is received,
either input.
ON = Energized.
ON = Energized.
ON = Energized.
ON = Energized.
ETHERNET LED on Cover: Flashing = Ethernet activity
ETHERNET JACK:
Green/Left ON = good link
Yellow/Right is ON = 100 Mb/s and OFF = 10 Mb/s
PLT-04233, Rev. A.3