- ページ 2
配管製品 Kohler 10EKDのPDF 取付説明書をオンラインで閲覧またはダウンロードできます。Kohler 10EKD 17 ページ。
Kohler 10EKD にも: インストレーション・インストラクション (4 ページ)
Procedure
1.
Remove the generator set from service.
1.1
Push the generator set power button OFF.
1.2
Disconnect power to the battery charger, if
equipped.
1.3
Disconnect the generator set engine starting
battery, negative (--) lead first.
2.
Remove the sound shield, if equipped.
2.1
Remove the three 5/16 in. x 2.5 in. bolts from the
sound shield roof. See Figure 1.
Top View
1
1. 5/16 in. x 2.5 in. bolts (qty. 3)
Figure 1 Roof Bolt Removal
2.2
Release the two latches on the service side door
to remove the service-side door. See Figure 2.
Service-Side View
1. Latches (qty. 2)
Figure 2 Service-Side Door Removal
2.3
Remove the 5/16 in. x 1.75 in. bolt to remove the
engine end door. See Figure 3.
2
GM55219C
1
GM55219C
Engine-End View
1. 5/16 in. x 1.75 in. bolt
Figure 3 Engine-End Door Removal
2.4
Remove the 5/16 in. x 1.75 in. bolts to remove the
exhaust panel and the generator-end door. See
Figure 4.
Generator-End View
1
1. 5/16 in. x 1.75 in. bolt on exhaust panel
2. 5/16 in. x 1.75 in. bolt on generator-end door
Figure 4 Exhaust Panel and Generator-End Door
Removal
2.5
Remove the two 5/16 in. x 0.625 in. bolts on the
nonservice-side door.
removed, remove the roof and remaining panels.
Nonservice-Side View
1
1. 5/16 in. x 0.625 in. bolts (qty. 2)
Figure 5 Nonservice-Side Door Removal
1
GM55219C
2
GM55219C
After these bolts are
GM55219C
TT-1617
12/13