Once in the command line interface (CLI) type "telnet", then the IP
address of the unit you wish to and "23", then hit enter.
Note: The IP address of the Matrix can be displayed on the device's
LCM monitor by pressing the Menu button twice.
This will bring us into the device which we wish to control. Type "HELP"
to list the available commands.
Type "IPCONFIG" To show all IP configurations. To reset the IP,
type "RSTIP" and to use a set static IP, type "SETIP" (For a full list of
commands, see Section 6.7).
Note: Any commands will not be executed unless followed by a
carriage return. Commands are not case-sensitive. If the IP is changed
then the IP Address required for Telnet access will also change
accordingly.