DSC Classic PC1565 빠른 매뉴얼 - 페이지 10
{카테고리_이름} DSC Classic PC1565에 대한 빠른 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DSC Classic PC1565 18 페이지. Security control panels
Wiring
Wiring SAB
These bell diagrams indicate how to
connect various bells to the Classic
PC1565. Take note that the strobe
should be connected to PGM 1 and
this is programmed as default for your
strobe connection.
The bell circuit on the Classic PC1565
is always supervised with a 1K resistor.
Bell/Panel Tamper Connections
Using a Relay
8
Wiring SAB
Basic Programming
Once you press [#] to exit section
005, the keypad will again display
"Enter Section" followed by three
dashes.
If you want to make changes to
another section, then enter that new
section number. If you want to exit
engineering mode, simply press [#]
once more and the keypad will revert
to normal mode.
Let's look at changing the default
setting of single end of line resistors
to our recommended double end of
line resistors.
Open the Installation Manual to page
29/30, and find section 013, First
System Option Code; section 013 is a
toggle option section. Section 013 will
be displayed on the LCD keypad as 2
lines, the first line displays "Toggle
Option" and the second line displays
which options are toggled "ON" or
"OFF". If a number appears, that
option is "ON". If a dash is displayed it
means that option is "OFF". If you are
using the LED keypad this will be
illustrated by the zone LEDs "ON" or
"OFF". We see that option 2 is "OFF"
because we see a dash, not a number.
Looking at section 013 in the
worksheets we see option 2 "OFF" in
section 013. This means that the
panel is set up for single end of line
resistors. If the option were "ON", the
number 2 would appear and the panel
would be set for double end of line
resistors.
Basic Programming
25