Overhang Support

Depending on the application, you might be required to provide overhang support for the
countertop.
Following are some guidelines to follow when working with overhangs.
Requirements
Support not required
Full sub top with corbels
Full sub top with legs or
columns
Raised bar mounted on top of
pony wall
9
2cm ONE Quartz
Overhangs under 12".
Use full sub tops greater than 6".
12" – 18" use full sub top along
with corbels evenly spaced at 3'
on center or less.
Overhangs over 18" use full sub
top along with legs or columns
connected at the top with rails of
adequate size to provide
perimeter support.
Full sub top and bracket or corbel support at 3' on center or less is
always required.
ONE Quartz
3cm ONE Quartz
Overhangs under 16"
16" – 24" use full sub top along
with corbels evenly spaced at 3"
on center or less.
Over over 24" use full sub tio
along with legs or columns
connected at the top by rails of
adequate size to provide
perimeter support.