activTek AP3000 매뉴얼 - 페이지 9
{카테고리_이름} activTek AP3000에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. activTek AP3000 16 페이지. Portable whole home office system
activTek AP3000에 대해서도 마찬가지입니다: 사용자 설명서 (12 페이지), 사용자 설명서 (12 페이지)
GENERAL MAINTENANCE
CAUTION:
Periodic maintenance is required to ensure that your AP3000 by activTek operates properly. The unit will display a PERFORM
CLEANING reminder when it's time to perform regular maintenance. If you are operating your unit in a severely polluted
environment, cleaning of the unit, purifier plate, ActivePure® (RCI) Cell, and Filter Assembly should be done more frequently.
Shown here are basic procedures that should be carried out to keep your unit running at top performance. For optimal
performance, and to prevent damage not covered by your warranty, install the optional AP3000 purifier prefilter. Failure to
perform routine maintenance could adversely affect the proper function of the unit or cause it to fail prematurely.
NOTE:
If a unit is returned for repair, and it is determined that neglect of the unit or unauthorized tampering with
any mechanical or electronic component of the unit caused the failure, activTek reserves the right to void the
product warranty . This will require the owner to pay for any required repairs .
CLEANING THE CASE:
Wipe the unit with a soft cloth dampened (not wet) with water . Do not use chemicals or solvents . Vacuum the front and
rear grills periodically to remove any lint buildup .
CLEANING THE ACTIVEPURE® (RCI) CELL:
Remove the ActivePure® (RCI) Cell and carefully vacuum accumulated lint . Do not wash the ActivePure® (RCI) Cell .
Damage from water may result .
FILTER ASSEMBLY CLEANING:
You have two options to clean the Filter Assembly:
1 . When visibly dirty, simply remove the Filter Assembly from the unit (see pages 11 - 12), and with a hand-held vacuum,
remove the heavy particulate . This method will extend the life of the Filter Assembly .
2 . When visibly dirty, remove the Filter Assembly from the unit (see pages 11 - 12), carefully vacuum, then wash in hot
water (do not use soap) . Allow to dry prior to reinstalling . Replace if damaged
FILTER ASSEMBLY REPLACEMENT:
Contact your activTek Distributor for replacement filters . See pages 11 - 12 for removal and installation instructions .
CLEANING THE PURIFIER PLATE:
Remove the Filter Assembly (see pages 11 - 12) . Carefully remove the purifier plate from the card cage by grasping the
middle of the edge nearest to you, and slowly pull it straight out . If you are in an environment where there are fats, oils,
or grease, such as in a kitchen, start by cleaning with denatured alcohol and a soft bristle brush . This will cut the grease
without leaving a residue .
For all applications – Clean with a mixture of one part water and one part ammonia to remove contaminants . Place the
plate into a shallow dish, and pour enough of the water/ammonia solution into the dish to just cover plate . Allow the
plate to soak for no more than 10 minutes .
Remove plate and scrub with a soft bristle brush . Rinse thoroughly . Let air-dry for 24 hours or use a blow dryer to dry
thoroughly . The unit will display a REPLACE PLATE message if the purification plate needs to be replaced .
CHANGING THE ACTIVEPURE® (RCI) CELL:
The ActivePure® (RCI) Cell should be replaced every year if used continuously, even if the unit does not display this
message . Replace every two (2) years if used less than 12 hours a day . To change the ActivePure® (RCI) Cell, follow the
instructions on pages 11 - 12 .
CAUTION:
Unplug the unit before performing any maintenance procedures .
Damage may result from soaking the purifier plate in the ammonia solution for more than
10 minutes .
.
9