HP Xw460c - ProLiant - Blade Workstation에 대해서도 마찬가지입니다: 구현 매뉴얼 (35 페이지), 오류 방지 매뉴얼 (12 페이지), 기술 백서 (12 페이지), 펌웨어 업데이트 (9 페이지), 설치 매뉴얼 (2 페이지), 자주 묻는 질문 매뉴얼 (14 페이지), 설정 포스터 (9 페이지), 설치 매뉴얼 (33 페이지), 하드웨어 매뉴얼 (23 페이지), 개요 (35 페이지), 사용자 설명서 (33 페이지), 최적화 매뉴얼 (13 페이지), 제한 보증 (10 페이지), 설치 지침 매뉴얼 (10 페이지), 설치 지침 매뉴얼 (8 페이지), 설치 지침 (4 페이지), 설치 지침 (2 페이지)

HP Xw460c - ProLiant - Blade Workstation 관리 매뉴얼
standby to increase overall enclosure power subsystem efficiency. When Dynamic Power Savings
mode is disabled, all power supplies share the load equally.

Enclosure bay IP addressing

The Onboard Administrator significantly enhances the management network infrastructure by offering
a single point from which to assign IP addresses to the server blade iLO 2 management ports and the
interconnect module management ports. By default, the Onboard Administrator, iLO 2, and supported
interconnect module management processors such as Virtual Connect Manager are configured to
acquire an IP address using Dynamic Host Configuration Protocol (DHCP) on the external
management network. For installations using static IP addressing, the Onboard Administrator offers
Enclosure Bay IP Addressing (EBIPA) as an alternative to manual configuration.
If EBIPA is enabled and the management ports are set to receive an IP address using DHCP, the IP
address settings can be managed by the Onboard Administrator using EBIPA. Using the autofill
feature, the administrator can input a range of IP addresses into the OA form (Figure 10). For
example, if the address of bay 1 is input as 12.240.62.11, autofill creates consecutively numbered IP
addresses for bays 2 through 16, starting with 12.240.62.12. IP addresses can be assigned to
unpopulated bays. Once a server or interconnect module is inserted into an EBIPA-enabled bay, it will
receive the pre-set IP address for that bay as well as the Shared Device Settings.
EBIPA settings are also present in the First Time Setup Wizard. There they provide the same
functionality; however, the wizard allows the address range to span multiple enclosures.
Figure 10. Onboard Administrator web GUI – Device Bay EBIPA settings
11