OPERATING INSTRUCTIONS

The tabletop heater is for outdoor use only. Always
ensure that adequate fresh air ventilation is
provided.
Always maintain proper clearance to combustible
materials, i.. e. top 18" and sides 24" minimum.
Tabletop heater must be located on a stable and
strong surface.
Never operate heater in an explosive atmosphere
such as in areas where gasoline or other flammable
liquids or vapors are stored.
LEAK TEST
1. Make 2-3 oz. of leak test solution
(one part liquid dish washing
detergent and three parts water).
2. Apply several drops of solution
where hose attaches to regulator.
3. Apply several drops of solution
where regulator connects to cylinder.
4. Make sure all patio heater valves are OFF.
5. Turn cylinder valve ON.
IF BUBBLES APPEAR AT ANY CONNECTION, THERE IS A LEAK.
1. Turn cylinder valve OFF.
2. If leak is detected at hose/regulator connection, tighten connection and
perform another leak test. If bubbles continue to appear, call our customer
service hotline at (866) 985-7877, 9 a.m. – 6 p.m., EST, Monday – Friday.
3. If leak is detected at regulator/cylinder valve connection, disconnect,
reconnect, and perform another leak test. If you continue to see bubbles
after several attempts, cylinder valve is defective. Call our customer service
hotline at (866) 985-7877, 9 a.m. – 6 p.m., EST, Monday – Friday.
IF NO BUBBLES APPEAR AT ANY CONNECTION, THE CONNECTIONS
ARE SECURE.
Note: Whenever gas connections are loosened or removed, you must perform
a complete leak test.
Contact us for assistance: (866) 985-7877 | www.wtliving.com
TABLETOP HEATER LOCATION
• Perform all leak tests outdoors.
• Extinguish all open flames.
• NEVER leak test when smoking
• Do not use heater until all connections
have been leak tested and show no signs
of leakage.
BEFORE TURNING GAS SUPPLY ON:
WARNING
BEFORE LIGHTING:
1. Your heater was designed and
approved for OUTDOOR use
only. Do NOT use it inside a
building, garage, or any other
enclosed area.
2. Make sure surrounding areas are
free of combustible materials,
gasoline, and other flammable
vapors or liquids.
3. Ensure that there is no
obstruction to air ventilation. Be
sure all gas connections are tight
and there are no leaks.
4. Be sure the cylinder is clear of
debris. Be sure any component
removed during assembly or
servicing is replaced and
fastened prior to starting.
1. Heater should be thoroughly
inspected before each use, and
by a qualified service person at
least annually. If re-lighting a
hot heater, always wait at least
5 minutes.
2. Inspect the hose assembly for
evidence of excessive abrasion,
cuts, or wear. Suspected areas
should be leak tested. If the
hose leaks, it must be replaced
prior to operation. Only use the
replacement hose assembly
specified by the manufacturer.
9