7.3 Wrap the group to be spliced with the conductor
group holder. Dress the pairs over the colored peaks
with the conductor ends exiting towards the color
code guide. Do not pull the conductors tight to the
back of the connector. Use the error tester tool to
check for correct conductor placement.
7.4 Spread the conductors around the "T" bar without
disturbing them in the module body. Pull the "T" bar
up above the module body. Push the "T" bar forward
and down until contact is made with the conductors.
Pull the handle down to the stop, seating and cutting
the excess conductors in the module body. Remove
the excess conductors. Engage the handle into the
retaining clip, pull the "T" bar up, and place into the
open position.
7.5 Place a cap on the module body. Use finger pressure
to push down the cap to pre-engage it to the module
body. The cap latches should face the color code
guide. Pull the "T" bar up above the cap. Push the
"T" bar forward and down until contact is made with
the cap. Pull the handle down to the stop, seating the
cap into the module body. Engage the handle into the
retaining clip, pull the "T" bar up, and place into the
open position.
7.6 Remove the bottomless module from the splicing rig.
The 25-pair bottomless module is complete.