Speci cation
MTL10 & MTL20 Mk2
Test Lamps
General
Power: from circuit under test
Dimensions: 213(L) x 112(W) x 72(D) mm.
Weight packed:
MTL10 – 320g approx.
MTL20 – 350g approx.
Includes: 2pc. Straight prod, 1pc. L-shaped prod, instructions
Safety
Conforms to BS EN 61243-3 CAT IV 600V, CAT III 1000V.
Class II, Double Insulation.
Pollution Degree: 2
IP rating: IP64
EMC
Conforms to BS EN 61326-1.
Electrical
Maximum working voltage: 500V AC, 750V DC
Nominal voltage threshold indications: 50, 120, 230, 400V AC/DC
Nominal voltage threshold tolerance: Conforms to BS EN 61243-3:2010
Range detection: Automatic
Response time: <0.1s
Frequency range: DC, 40-65Hz
Switchable load (MTL20 only): approx. 8.8k load
Test current:
MTL10 & MTL20 (switches not operated): <3.5mA at 500V AC rms, 750V DC
MTL20 (switches operated):
approx. 28mA at 230V AC rms, DC
approx. 60mA at 500V AC rms, DC
Duty ratio: 30s ON (operated) / 240s OFF (recovery)
Environmental
Temperature (Operating & Storage): -10°C to 55°C
Humidity (Operating & Storage):
Altitude: up to 2000m
15
05/12/2013 11:31:06
MTL10 MTL20 instructions rev8.indd 5
Check out what else you can get from Martindale:
•
17th Edition Testers
•
Accessories
•
Calibration Equipment
•
Continuity Testers
•
Electricians' Kits
•
Environmental Products
•
Full Calibration & Repair Service
•
Fuse Finders
•
Digital Clamp Meters
•
Digital Multimeters
•
Labels
•
Microwave Leakage Detectors
Registered in England No. 3387451. E. & O.E. Document Rev8
Speci cation
MTL10 & MTL20 Mk2
Test Lamps
85% R.H.
•
Motor Maintenance Equipment
•
Multifunction Testers
•
Non-trip Loop Testers
•
Pat Testers & Accessories
•
Phase Rotation Testers
•
Proving Units
•
Socket Testers
•
Thermometers & Probes
•
Test Leads
•
Voltage Indicators
•
Specialist Metrohm Testers (4 & 5kV)
•
Specialist Drummond Testers
Martindale Electric Company Limited
Metrohm House, Imperial Park, Imperial Way,
Watford, Hertfordshire, WD24 4PP, UK
Tel: +44(0)1923 441717 Fax: +44 (0)1923 446900
E-mail:[email protected]
Website: www.martindale-electric.co.uk
© 2016 Martindale Electric Company Ltd.
05/12/2013 11:31:05