※ • B e•sure•that•if•selecting•'Default.pms'•file,•every•
set•value•is•initialized•as•factory•default.•Save•the•
current•set•parameter•as•Save•Set•File•(parameter•
setting•file•storage)•at•first•and•initialize•it•for•the•
provision.
※ One file from•User1.pms•to•User5.pms,•User1.pms•
(USB)•to•User5.pms(USB)•is•selected,•all•parameter•
setting•information•of•KRN100•is•changed•as•the•set•
value•of•the•selected•parameter•save•file.•
※ • S et•value•changing•may•be•also•affected•to•every•
setting•of•KRN100's•overall•operations.•Check•
possible•problems•occurring•on•system•and•change•
the•desired•set•value.
٧ Save parameter set file [ Save Set File ]
Saves•current•set•parameter•set•value•to•inner•memory•
or•an•external•USB•memory.
When•saving•it•to•inner•memory,•it•is•saved•in•User1.
pms•to•User5.pms•files•or•to•an•external•USB•memory,•
it•is•saved•in•User1.pms•(USB)•to•User5.pms•(USB)•
files.•(Activated•only•when•an•external•USB•memory•is•
connected.)•
• • Set•range:•
• None•↔•User1.pms•to•User5.pms,•User1.pms(USB)•
to•User5.pms(USB)•
• • Factory•default:•Select...•
٧ USB storage function [ USB LogData Save ]
Set•whether•to•save•backup•data•which•is•saved•at•
system•on•an•USB•memory.•
When•selecting•Enable•to•saving•data•to•USB•memory,•
it•also•saves•data•to•system•memory•at•the•same•time.•
Connected•an•USB•memory•at•left•side•USB•Slot,•
KRN100•starts•to•save.•It•takes•check•time•for•storage•
free•space•approx.•10•to•60•sec.•depending•on•memory•
capacity.
The•data•is•saved•as•'KRN100_20100815(year•month•
day)_091050(hour•min.•sec.).KRD'•file•name•and•if•
main•set•is•changed•or•backup•data•capacity•is•over•
100MByte,•it•creates•a•new•file.•
• • • S et•range:•Disable•↔•Enable
• • • F actory•default:•Disable
※ • S upporting•file•system•is•FAT16,•FAT32•when•using•
an•USB•memory.•Microsoft's•file•system,•NTFS,•
and•Linux's•file•system,•EXT2,•EXT3,•etc.,•are•not•
supportable.
※ • W hen•connecting•an•USB•memory,•KRN100•pauses•
backup•data•download•by•Modbus•function,•and•
backup•data•printer•function•to•recognize•memory•for•
a•while•(depending•on•the•capacity,•max.•30•sec).
※ • I f•an•USB•memory's•LED•flashes,•do•not•remove•an•
USB•memory,•or•it•may•damage•to•the•data.•If•the•
damage•of•USB•memory•data•occurs,•you•can•find•
the•saved•data•from•KRN100•inner•memory•and•
save•the•desired•file•to•an•USB•memory.
100mm Hybrid Recorder

Firmware upgrade

Upgrades•KRN100•firmware.
When•upgrading•firmware,•parameters'•set•values•are•
initialized.
• • • S et•range:•-
• • • F actory•default:•Auto•set•
※ • D uring•firmware•upgrade,•alarm•output,•digital•input•and•
log•file•save,•etc•functions•does•not•operate•normally.•
Therefore,•please•take•proper•measures•to•prevent•
malfunction•of•KRN100•system•before•starting•firmware•
upgrade.•After•completing•firmware•upgrade,•you•must•
turn•OFF•and•ON•the•power•of•KRN100•to•operate•
normally.•
※ • D uring•firmware•upgrading,•when•power•turns•OFF,•
firmware•upgrade•is•not•complete.•When•power•turns•
ON•again,•KRN100•operates•with•previous•firmware•
version.•Try•firmware•upgrade•again.•••
※ • A fter•completing•firmware•upgrade•and•OFF/ON•the•
power,•if•KRN100•displays•booting•screen•and•does•
not•operate•normally,•it•may•have•damage•to•the•inner•
firmware•during•firmware•upgrade.•It•is•required•to•
repair
Backup data record setting
[ RECORD BACKUP_ SETUP ]
Record•Backup•creates•file•when•power•ON•regardless•
of•starting/stopping•record•and•saves•the•data•to•inner•
system•memory•(USB•memory•storage•is•available•
(Enable)•by•the•set.)•according•the•set•record•mode.
This•parameter•is•useful•to•print•the•desired•time•data•with•
backup•data•or•check•data•by•computer•with•DAQ•Master•
(dedicated•software).
Therefore,•backup•data•set•function•is•for•printing•the•
saved•backup•data•at•inner•system•memory•and•USB•
memory.
Move•to•RECORD•BACKUP•SETUP•with•the•
keys•and•press•the•
•key•to•enter•RECORD•BACKUP•
SETUP.
※ • F or•printing•backup•data,•KRN100•reads•saved•backup•
data•in•memory•from•beginning•to•end•at•first•and•starts•
printing.•If•backup•data•section•is•long•or•backup•data•is•
saved•as•low•speed•record•mode,•reading•takes•a•lot•of•
time.•Therefore,•print•only•for•the•desired•section.
※ • I n•graph•mode,•record•speed•is•changed•by•Standard•
speed,•Alarm,•or•Option•Speed.•Backup•data•is•printed•
with•Standard•speed.•Therefore,•original•printout•and•
backup•printout•in•graph•mode•may•be•different.
٧ Backup data record for clearing no recording paper
[ P.END Backup Print ]
If•there•is•no•recording•paper,•the•
After•replacing•recording•paper,•「P.END•BACKUP•
PRINT」screen•as•below•is•activated.
Backup•data•recording•function•by•P.END•is•same•
as•RECORD•BACKUP.•Backup•Data•List•cannot•be•
changed.
Starting•print•by•P.END•Backup,•it•prints•the•data•but•
backup•data•file•date,•file•name,•and•backup•record•
starting•line.
A. Recorder
B.•Indicator
C.•Converter
D.•Controller
E.•Thyristor•
•••••unit
F.•Pressure•
••••transmitter
G.•Temp.•
•••••transmitter
H.•Accessories
KRN100
KRN50
,•
••
•icon•flashes.•
A-11