Keypad Installation Procedure:
Step 1: Drill through the back plate using a 11/64" bit. Use the template on the back page to accurately mark the mounting
holes before drilling. Then drill the mounting holes with a 9/64" drill bit. Also drill the hole for the wires. This may
vary depending on the number of conductors required.
Step 2: On the keypad end, strip back the insulator from the wire and tape the drain wire (shield) to the jacket. Now
connect the required wires to the 8-conductor wire harness provided. The wire harness plugs into the 8-position
connector on the keypad. At the other end of your wire run, strip back the insulator from the wire but do not tape
the drain wire to the jacket. The drain wire must be connected to ground at the controller end. See the diagrams
below.
Step 3: Finally mount the keypad onto the mounting surface using the provided screws. Do no over-tighten the screws,
which may result in damage.
Wiring the SSWiLM Keypad to a 232 Access Control Module
The connection between the SSWiLM Keypad and the 232 Controller requires a 4-conductor, stranded wire with overall
foil shield. The 8-conductor wire harness from the keypad connects to connector P6 on the controller. Connect the wires,
color to color (red to red, black to black, white/black to white/black and white/yellow to white/yellow). Refer to the wire
lengths on the fi rst page. As mentioned above, the drain wire must be attached to Ground on the controller side, which is
the V- terminal or negative of your power supply.