Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Indesit Arcadia. Indesit Arcadia 3 pagina's. Fault codes

Service Quick Guide
Service Quick Guide
FAULT
Main PCB, Triac on board damaged or
F01
components Feedback fault
Motor tripped, motor tachogenerator open
F02
circuit / or short circuit
F03
NTC wash sensor open / short circuit
1/3
SQG_WM_23/5_EN
Indesit Company, Service Department
Arcadia Fault Codes (Simple)
CAUSE
- Check for water leaks that may affect connectors J009 (Commuta-
- Check the motor terminal board (any problems due to aggression
- Check the connection on the wash heating element;
- Check effi ciency of connector J001 (Commutator) or J010
- Check connector J001 (Commutator) or J010 (Three-phase)
- Check for water leaks that may affect connectors J006 (Commuta-
- Check the terminal board (any problems due to aggression
- Check wiring of connectors J006 (Commutator) or J007 (Three-
- Disconnect appliance for 2 minutes. Check wiring and connec-
- Check that correct operation has been restored by starting the
- Renew main PCB.
- Check for water leaks that may affect connector J9 causing the
- Check to ensure motor is not mechanically jammed or seized;
- Check effi ciency of the contacts on connector J9 on the PCB;
- Check the motor side connector;
- Check motor winding and check that the impedance value on
- Check the tachogenerator winding and check that the impedance
- Check the tachogenerator wiring;
- Disconnect appliance for 2 minutes. Check that correct operation
- Renew motor;
- Renew PCB.
- Check effi ciency of contacts on connector J005 (commutator)
- Check NTC ensuring that the impedance value at ambient
- If measurement is incorrect check continuity of wiring J005
- Check the same parameter directly on the NTC (20 KOhm);
- Renew NTC;
- Renew PCB.
SERVICE ACTIONS
tor) or J009 (Three-phase) causing the relative contacts to short;
caused by manufacturing chemical residues that may cause
short circuits);
(Three-phase) on the PCB;
pins 3 and 4 for continuity of the wash heating element (1700
watt - 230 volt) which must be 30 Ohm +/- 10%. Otherwise,
renew heating element;
tor) or J007 (Three-phase) causing the relative contacts to short;
caused by manufacturing chemical residues that may cause
short circuits);
phase)/Pressure switch;
tors of the dryer heating element on main PCB board side and
component side;
Autotest routine;
contacts to short circuit;
wiring connector J9 between pins 3 and 4, 4 and 5, 3 and 5 is
less than 100 Ohm;
value on wiring connector J9 between pins 1 and 2 is between
115 and 170 Ohm;
has been restored by starting the Autotest routine;
or J12 (three-phase) on PCB;
temperature (20°C) on wiring connector J005 (commutator) or
J12 (three-phase), pins 1 and 2, is approximately 20 KOhm;
(commutator) or J12 (three-phase), pins 1 and 2/NTC;