CAME 9T90EN Instrukcja instalacji - Strona 2
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Panel sterowania CAME 9T90EN. CAME 9T90EN 12 stron. Control panel for 230 v - 400 v gearmotors

"WARNING: IMPROPER INSTALLATION MAY RESULT IN SERIOUS HARM. PLEASE FOLLOW ALL INSTALLATION INSTRUCTIONS"
"THIS MANUAL IS INTENDED ONLY FOR PROFESSIONAL INSTALLERS OR OTHER COMPETENT INDIVIDUALS"
1 Legend of symbols
This symbol shows parts which must be read with care.
This symbol means the parts which describe safety issues.
This symbol tells you what to tell the end-user.
2 Intended use and limits to use
2.1 Intended use
The ZT6 - ZT6C control panel is engineered by Came Cancelli Automatici S.p.A. for commanding 001BK-2200T sliding gates as well
as 001C-BXT sectional, sliding and folding door operators.
Any installation and use other than that specified in this manual is forbidden.
2.2 Limitations to use
The overall power of the gearmotor when connected must not exceed 780 W.
3 Reference standards
Came Cancelli Automatici employs an ISO 9001 certified quality management system and an ISO 14001 environmental management
system. Came only engineers and manufactures in Italy.
This product is compliant with: see statement of compliance.
4 Description
Single and tri-phase 230 V AC or 400 V AC tri-phase power
supply. The control panel is protected by a 8 A fuse, while the
low voltage accessories (24 V) are protected by a 2 A fuse.
The ZT6C control panel comes with safety block and 3-hard
wired buttons (stop, open, close) on the case cover.
Warning! The overall power of the 24 V accessories must not
exceed 20 W.
The card provides and controls the following features:
- automatic closing;
- partial opening for pedestrian passage;
- obstacle detections when gate is not moving at any point;
- maintained action;
- Pre flashing by the flashing light;
- Running the safety test feature.
The available command modes are:
-opening/closing;
-opening/closing with maintained action;
- open-stop-close-stop;
- Partial opening;
- total stop.
The photocells, after detecting an obstacle, may trigger:
- the reopening of the closing gate;
- the reclosing of the opening gate;
- a partial stop;
- a total stop.
Specific trimmers regulate:
- the working time for automatic closing;
- the partial opening time.
"IMPORTANT INSTALLATION SAFETY INSTRUCTIONS"
You can also connect:
- a courtesy lamp to light up the driving area for a set time;
- a lamp to light up the driving area during the open/close
cycles.
Protection rating of the container IP54
T E C H N ICA L DATA
Power supply 230 V / 400 V - 60 Hz
Maximum power rating 780 W
Power draw when idle
Maximum power for 24 V
accessories
Maximum power for 230 V
accessories
Circuit insulation class
Container material ABS
Working temperature - 20 / +55°C
FU SE TA B LE
to protect: fuses for:
Electronic board (line) A 8
Accessories A 2
Command devices (control unit) A 630
50 mA
45 W
85 W