DOOVAC MVO-100 Instruções de instalação - Página 2

Procurar online ou descarregar pdf Instruções de instalação para Bomba de água DOOVAC MVO-100. DOOVAC MVO-100 11 páginas. Vacuum pump

Maintenance guide
Oil injection, power connection, connect suction pipe
1. Product basic component
Nameplate
Inlet port
Vacuum oil
2. Oil injection
Unstop the oil inlet
Inject the product's particular oil
- Note : Oil standard chart
Fill up to "MAX" in an oil gauge.
- Note : Oil standard chart
Make sure to check the o-ring
in an oil inlet and reassemble
the parts.

Vacuum pump installation

Oil inlet
MVO-100
[ DM-F002 ]
[ DM-F002 ]
3, Connect the power
Disassemble the
electricity box's cover.
Check the wiring diagram
inside of the electricity box
and connect the wires.
After perforating the side of
the electricity box, connect
the power.
Check the rotation direction
of cooling blade.
Warning :
No match of voltage and frequency
will cause a severe damage to the
motor.
Warning :
A backlashing of the motor will
Cause a severe damage to vacuum
pump.
4. Connect suction pipe.
Remove the rubber stopper in
an inlet and Connect the suction
pipes.
Warning :
In case of any foreign substances
coming into the pump, it will
cause severe damages to rotor
and vane. In this case, installation
of an extra filter on suction pipe
is necessary.
LV.1~2
PF002
2/11