DOOVAC MVO-100 Instruções de instalação - Página 3

Procurar online ou descarregar pdf Instruções de instalação para Bomba de água DOOVAC MVO-100. DOOVAC MVO-100 11 páginas. Vacuum pump

Oil injection, power connection, connect suction pipe
Maintenance guide
1. Oil injection
Remove the oil inlet's stopper and inject the product's particular oil in the extra container to "up to max line of
an oil gauge" and close the stopper.
Make sure to assemble when O-RING is in an oil inlet stopper.
Graphic 1. each part's name of an oil inlet
2. Connect the power (three phase power)
1) Check the working place's
main power and the power
of the motor's nameplate.
5) Connect the power as
perforating the side of a
socket box
3. Connect suction pipe.
Removal of a rubber
stopper
Vacuum pump installation
Oil inlet stopper
Oil gauge
Oil outlet stopper
2) Remove a cover of
the motor's socket box
6) Make sure to check
the rotation direction and
power
Connect an inlet pipe
Graphic2. oil injection
3) Check the wiring
diagram inside of the
cover
Warning :
No match of voltage and frequency
will cause a severe damage to the
motor.
Warning :
A backlashing of the motor will
Cause a severe damage to vacuum
pump.
Warning :
In case of any foreign substances
coming into the pump, it will cause
severe damages to rotor and vane.
In this case, installation of an extra
filter on suction pipe is necessary.
LV.1~2
PF002
3/11
O-RING
Graphic3. O-ring
4) Connect the inside of
terminal block in accordance
with the working place's
power