ACU-RITE SENC 150 Manual de referência - Página 16
Procurar online ou descarregar pdf Manual de referência para Conversor de multimédia ACU-RITE SENC 150. ACU-RITE SENC 150 20 páginas. Chevalier fsg-2a 1224 surface grinder cross feed “x” axis
Também para ACU-RITE SENC 150: Manual de instalação (8 páginas), Manual de instalação (4 páginas), Manual de instalação (6 páginas), Manual de instruções (12 páginas)
8 Checking the mounting
Connecting the encoder
Route the cables with slack loops
to allow for axis motion.
Secure excess cable by fastening
with clips or ties.
Attach the linear encoder connectors
to the readout.
Checking the electrical shielding
Connect a ground wire from the
terminal on the back of the readout to
the machine or earth ground.
Attach a ground wire from the machine
to a solid earth ground.
With the encoder attached to the ma-
chine and the cable connected to the
readout, check shielding by measuring
resistance between connector housing
and scale unit.
Desired value: 1 Ω max.
16
SENC 150