3E THERMOSALD ISC Manual de início rápido - Página 12
Procurar online ou descarregar pdf Manual de início rápido para Controlador 3E THERMOSALD ISC. 3E THERMOSALD ISC 20 páginas. Temperature controller for impulse sealing. modular system
NOTE – If calibration problems arise, perform a MASTER RESET procedure starting from stage 5.
To perform a MASTER RESET procedure, use either of the two modes below:
mode 1 – Keep the ARROW DOWN + ARROW UP buttons pressed for 6 seconds.
mode 2 - Keep the external RESET+CALIBRATION buttons pressed for 6 seconds.
The four LEDS on the equipment stay on for 3 seconds
4.4 - PUTTING THE SYSTEM INTO SERVICE – BASIC SETUP + MULTI-LINGUAL PANEL +
POTENTIOMETERS (+RS485 OPTION)
NOTE 1: Perforn the same operations as those described in paragraph 4.3 above.
NOTE 2: To enable the potentiometers, change the MACHINE DATA items = 1, Potentiometers + display.
NOTE 3: Set the maximum pre-heat and heat-seal temperatures by using the control panel. To step them down, adjust the
analog inputs (for resolution see technical note paragraph 4.1).
THERMOSALD ISC – MANUAL QUICK START
Manual cod.: 3ES080x_V5.1_QS_EN
Includes all previous models
Page Nr.
12
PRE-HEAT POTENT.
HEAT-SEAL POTENT.
CLEAR FAULTS/ RESET
BUTTON
CALIBRATION BUTTON
Rev. 2010 / 03
Tot. Nr . 20