4. ELECTRICAL CONNECTIONS
All condensing units must be operated on 230 volt, 60 cycle,
single phase electrical supply.
Water pump and agitator motors are to be operated on
115 volt, 60 cycle, single phase electrical supply.
5. CONTROL PANEL
All DARI-KOOL Bulk Milk Coolers have a control panel
where electrical connections will be made by the installer.
Fused switch boxes should be provided for protection.
In the control pane] or on the side section of the cooler there is
also:
A. THERMOMETER-Easy to read dial which is in direct
contact with milk tank to give you exact temperature of milk.
B. TEMPERATURE CONTROL-Adjustable to tempera­
ture setting required by your milk plant. This controls the
automatic operation of the water pump and agitator.
The
setting on the control is the shut-off point which means when
the milk is cooled to this temperature the pump and agitator
will shut off.
Also, when milk temperature rises several
degrees the pump and agitator will start again.
C. TIMER-At certain times it is necessary to run agitator
and pump even though the temperature control is not call­
ing for it. To accomplish this we have incorporated a timer
which by-passes the temperature control. The timer can be
set to any position up Lo 120 minutes and the pump and agi­
tator will function that length of time though the tempera­
ture has reached the preset temperature on the control. The
timer is used by the milk hauler to get a composite sample
and you can use it for cooling milk. To do this we recom­
mend that 10 or 15 minutes before starting to add milk to
the cooler you set the timer. This will insure you of cooling
prior to the time the temperature control is calling for cooling.
As soon as the milk has warmed up enough for the tempera­
ture control to take over, the timer will continue to run back
to zero and the temperature control will take over for auto­
matic control of pump and agitator.
D. ICE BANK CONTROL-The operation of the condens­
ing unit is controlled by the ice bank control. The amount
of ice built on the coils is determined by the distance the
bulb is from the coil.
This distance is set at the factory
and no adjustment should be attempted by anyone except
authorized DARI-KOOL dealers or Service Personnel.
As
a matter of information you may find the condensing unit
- 3 ­