Galvin Engineering Ezy-Drink Lead Safe SS316 Мануалы по установке - Страница 3

Просмотреть онлайн или скачать pdf Мануалы по установке для Сантехническая продукция Galvin Engineering Ezy-Drink Lead Safe SS316. Galvin Engineering Ezy-Drink Lead Safe SS316 4 страницы. Remote push button drinking bubbler

Product Installation Guidelines
3. Tighten locknut and fit handle
To resist theft/vandalism, ensure the
stainless steel locknut is tightened firmly
using an appropriate wrench.
5. Fit flexi-hose
Fit flexi hose to outlet and body as shown.
© Galvin Engineering Pty Ltd
4. Secure push button handle
Lock push button handle in place by fitting grub
screw and tightening using 2mm hex key. Take
care not to overtighten.
6. Testing
Once the drinking tap has been installed and tested
for leaks, the water height must be adjusted to suit
the available pressure.
To adjust water flow
1. Remove the blanking screw .
2. Adjust the water height by turning the regulator
screw .
3. Replace blanking screw.
Note: The full range from minimum flow to maximum
flow is only ¼ turn.
th
Version 4, 25
October 2022, Page 3 of 5