Connector mounting
5. Connector mounting
–
Strip approx. 35 mm of the cable and remove approx. 5 mm insulation from each wire
end.
–
Loosen the screw 1.
–
Lever the terminal holder 5 out of the enclosure 2 using the mounting hole on the seal
6.
–
Unscrew the cable fitting 4 and take out the cable seal 3.
–
Lead the cable through the cable fitting 4 and the cable seal 3 in the enclosure 2.
Inproper mounting.
►
NOTICE
Enclosure seal can become damaged.
Do not push the terminal holder 5 out using the screw hole or the cable fitting 4.
–
Unscrew the cable fitting 4 and take out the cable seal 3.
–
Lead the cable through the cable fitting 4 and the cable seal 3 in the enclosure 2.
–
Connect the cable ends in accordance with the wiring diagram (Fig. 4.1).
–
Loosen the screw terminals of the terminal holder 5, connect the stripped wire ends in
accordance with the wiring diagram (Fig. 4.1) and screw the screw terminals in tight.
–
Put the terminal holder 5 and snap the connector seal 6 in the enclosure 2.
–
When screwing the cable fitting 4, make sure the cable fitting 4 with the cable seal
are assembled correctly and the cable seal 3 is not damaged.
–
Plug the socket (2+5+6) to the contacts 7.
–
Tighten the screw 1.