Baumer EAM ST Series Manuel - Sayfa 11

Medya Dönüştürücü Baumer EAM ST Series için çevrimiçi göz atın veya pdf Manuel indirin. Baumer EAM ST Series 28 sayfaları. Absolute encoder with canopen

5 NMT Service

5.1

Supported commands

Following NMT commands are supported:
NMT Command
NMT Start
NMT Preoperational
NMT Stop

NMT Reset

NMT Communication Reset

NMT Frame:
COB ID
Byte 0
node ID
xx
NMT Reset
5.1.1
This NMT command performs a complete reset of the encoder, which can take up to 170 ms until the new bootup-
message is sent (restarting of the micro controller, be aware that all unsaved configurations will be lost).
NMT Communication Reset
5.1.2
This NMT command performs a restarting of the CAN Controller, which can take up to 5 ms until the new bootup-
message is sent (be aware that all unsaved configurations will be lost).
5.2

Boot-up message

After a power-on or NMT reset, the device will send a Boot-up message.
COB ID
Byte 0
700h + node ID
00