Smoke Sensor (RMA-SS1-SEN)
Before you begin:
Read
Avoid These Locations
Step 1: Attach the included Mounting Bracket to the ceiling (or wall).
1. Remove the mounting bracket from the Smoke Sensor base by holding the Smoke
Sensor and twisting the mounting bracket clockwise (right). (Set the unit aside where
it won't get covered with dust when you drill mounting holes later.)
2. Hold the mounting bracket against the ceiling (or wall) and mark the center of each of
the mounting slots with a pencil.
3. Using a 3/16" (5 mm) drill bit, drill a hole through each pencil mark.
4. Insert the included plastic screw anchors into the holes. Tap the screw anchors gently
with a hammer, if necessary, until they are flush with the ceiling or wall.
5. Tighten the included screws into the screw anchors.
Step 2: Activate the included battery.
Your Smoke Sensor ships to you with the battery in backwards to prevent the sensor from
alarming during transit. To activate the battery:
1. Open the Battery Compartment of the Smoke Sensor.
2. Re-insert the battery so its terminals match the terminals on the Smoke Sensor:
match "+" to "+" and "-" to "-". Push the battery in until it snaps in securely. (Note
that the Smoke Sensor may beep briefly when you install the battery.)
3. Close the Battery Compartment.
Step 3: Attach the Smoke Sensor to the mounting bracket.
Position the base of the Smoke Sensor over the mounting bracket and turn clockwise
(right) until the unit is in place.
Do not paint over the Smoke Sensor. Paint may clog the openings to the sensing
chamber and prevent the unit from operating properly.
Step 4: Test your Smoke Sensor
See
Test Your Smoke Sensor
in this document for placement recommendations.
in this document for instructions.