Smoke Sensor (RMA-SS1-SEN)
• In very damp, humid or steamy areas, or directly near bathrooms with
showers
Keep units at least 10 feet (3 meters) away from showers, saunas, dishwashers, etc.
• Where the temperatures are regularly below 40° F (4.4° C) or above 100° F
(37.8° C)
• In very dusty, dirty or greasy areas
Do not install a Smoke Sensor directly over the stove or range. Keep laundry room
Smoke Sensors free of dust or lint.
• Near fresh air vents, ceiling fans or in very drafty areas
Drafts can blow smoke away from the unit, preventing it from reaching the sensing
chamber.
• In insect infested areas
Insects can clog openings to the sensing chamber and cause unwanted alarms.
• Less than 12 inches (305 mm) away from fluorescent lights.
Electrical "noise" can interfere with the sensor.
• In "dead air" spaces.
"Dead air" spaces may prevent smoke from reaching the Smoke Sensor. To avoid dead
air spaces:
▪
On ceilings, install Smoke Sensors as close to the center of the ceiling as possible.
If this is not possible, install the Smoke Sensor at least 4" (102 mm) from the wall
or corner.
▪
For wall mounting (if allowed by building codes), place the top edge of the Smoke
Sensor between 4" and 12" (102 and 305 mm) from the wall/ceiling line, below
typical "dead air" spaces.
▪
On a peaked, gabled or cathedral ceiling, install the first Smoke Sensor within 3'
(0.9 meters) of the peak of the ceiling, measured horizontally. Additional Smoke
Sensors may be required depending on the length, angle, etc. of the ceiling's slope.
Maintain Your Smoke Sensor
Test your Smoke Sensor
Test your Smoke Sensor at least once a week.
To test, hold down the Test/Silence Button until the alarm sounds and the Escape Light
Page 4